BN 1-2KW OFF-GRID INVERTER

Short Description:

The iMars BN series single-phase photovoltaic off net inverter adopts the traditional off-line power supply function combined with the solar power generation control, which provides flexible and safe system solutions for the uninterrupted power supply of the family and industry.


Product Detail

Product Tags

Product Description

Effcient
Multiple charging topology,to maxmize battery performance.
Multiple working priority settings.
Electricity bypass quick charging function.
Solar panel MPPT charging technology

Smart
Global integrated monitor management, APP with one-button registration.
Parallel operation up to 6 units.

Reliable
Over-load and short-circuit protection.
Capable of linear load or non-linear load.

Simple
Easy to maintain.

捕获

Slution

2
3
4

Product Certification

图片4

Product Spec

BN1012C/E

BN1024C/E

BN1512C/E

BN1524C/E

BN2012C/E

BN2024C/E

Line mode
AC input voltage (V)

220/230/240

Rated frequency (Hz)

50/60(auto detection)

Transfer time (ms)

(AC to DC or DC to AC):10(typical)

Bypass relay current (A)

30

Invert mode
Output voltage waveform

Sine wave

Rated output power (VA) / (W)

1000/1000

1500/1500

2000/2000

Rated output voltage (V)

220/230/240(±10%)

Rated Output frequency (Hz)

50±0.3/60±0.3

Efficiency

>88%

Over-load protection

(110%<load<125%) ±10%:="" fault(shutdown="" output)="" after="" 15min;
(125%<load<150%) ±10%:fault(shutdown="" output)="" after="" 60s<="" div="">

Peak power (10s) (VA)

3000

4500

6000

Output breaker current (A)

10

30

DC input voltage (V) /
Min. DC start voltage (V)

12VDC mode:12/11; 24VDC mode:24/22

DC input voltage range (V)

10.016.0, ±0.6Vdc:12VDC mode(*2 is 24VDCinput mode, *4 is 48VDC input mode)                                                                                     (12VDC mode:low alarm:10.5V; shut down:10V; high fault:16V; high recovery:15.5V)

Charge (Line)
Charge current (A)

35

20

45

25

65

35

Battery voltage range (V)

12VDC mode:10-15.7;  24VDC mode:20–31.4

Breaker current (A)

10

30

Over charge protection

Bat. V≥15.7 is 12VDC mode, (*2 is 24VDC input mode,*4is 48VDC mode)every 1s & fault after 60s

Charge (Solar) (E series is not included)
MPPT voltage range (V)

12VDC mode:15-55; 24VDC mode:18-78

Max. PV input voltage (V)

12VDC mode:70; 24VDC mode:100

Max. PV open circuit voltage (V)

12VDC mode:56; 24VDC mode:80

Rated charge current (A)

45

Max. full load charging efficiency

98%

Battery short-circuit protection

Fuse

General data
Dimension (H x W x D mm)

410x264x180

460x264x180

Weight (kg)

15.7

16

19.9

19

21.9

22

Degree of protection

IP20 (forced air, variable speed fan)

Operating temperature range

-15°C to 40°C(-25ºC60ºC for storage)

Communication interface

RS-485, GPRS, WiFi

Safe certificate / EMC certificate

CE(EN62040-1, EN62040-2)/C2

Factory warranty (years)

1

Application