Place of Origin:Shenzhen, China
Brand Name:GROWATT
Model Number:MIN 2500-6000TL-X solar inverter
Input Voltage:360VAC
Output Voltage:230VDC
Output Current:13.6A
Output Frequency:50/60 Hz
Output Type:TRIPLE, Multiple
Size:375x350x160mm
Type:DC/DC Converters, DC/AC Inverters
Warranty:5years
Weight:10.8kg
Product name:Growatt Solar Inverter
AC Auto Restart:Yes
Topology:Transformerlerless
Output waveform:Pure Sine Wave Solar Inverter
Bypass Efficiency:98%
Rated power:4.2kw
Application:COMMERCIAL ROOFS AND SMALL DISTRIBUTION PROJECTS.
Display:OLED+LED/WIFI+APP
Color:White
Growatt 30000-50000tl3-s Is Ideal For Commercial Roofs And Small Distribution Projects. Integrated Wire Box For Comprehensive Protections.
SIMPLE AND EASY TO USE
Touch key and OLED display
Type II SPD on DC side
Support export control
EFFICIENT POWER GENERATION
Max. efficiency 98.4%
DC/AC ratio upto 1.4
Dual MPP trackers
STRONG ADAPTABILITY
Battery ready(XH) interface extend to storage system at
anytime you want
+IoT make your energy smarter
MIN 2500-6000TL-X
Datasheet |
MIN 2500TL-X |
MIN 3000TL-X |
MIN 3600TL-X |
MIN 4200TL-X |
MIN 4600TL-X |
MIN 5000TL-X |
MIN 6000TL-X |
Input data (DC) | |||||||
Max. recommended PV power (for module STC) |
3500W |
4200W |
5040W |
5880W |
6440W |
7000W |
8100W |
Max. DC voltage |
500V |
500V |
500V |
500V |
500V |
500V |
500V |
Start Voltage |
100V |
||||||
Nominal voltage |
360V |
||||||
MPP voltage range |
80V-500V |
80V-500V |
80V-550V |
80V-550V |
80V-550V |
80V-550V |
80V-550V |
No. of MPP trackers |
2 |
||||||
No. of PV strings per MPP tracker |
1 |
||||||
Max. input current per MPP tracker |
12.5A |
||||||
Max. short-circuit current per MPP tracker |
16A |
||||||
Output data (AC) | |||||||
AC nominal power |
2500W |
3000W |
600W |
4200W |
4600W |
5000W |
6000W |
Max. AC apparent power |
2500VA |
3000VA |
3600VA |
4200VA |
4600VA |
5000VA |
6000VA |
Nominal AC voltage(range*) |
230V (180-280V) |
||||||
AC grid frequency(range*) |
50/60 Hz (45-55Hz/55-65 Hz) |
||||||
Max. output current |
11.3A |
13.6A |
16A |
19A |
20.9A | 22.7A | 27.2A |
Adjustable power factor |
0.8leading…0.8lagging |
||||||
THDi |
<3% |
||||||
AC grid connection type |
Single phase |
||||||
Efficiency | |||||||
MPPT efficiency |
98.20% |
98.20% |
98.20% |
98.40% |
98.40% |
98.40% |
98.40% |
European efficiency |
97.10% |
97.10% |
97.20% |
97.50% |
97.50% |
97.50% |
97.50% |
MPPT efficiency |
99.90% |
||||||
Protection devices | |||||||
MPPT efficiency |
Yes |
||||||
DC reverse polarity protection |
yes |
||||||
DC switch |
Type III / Type III |
||||||
AC/DC surge protection |
yes |
||||||
Insulation resistance monitoring |
yes |
||||||
AC short-circuit protection |
yes |
||||||
Ground fault monitoring |
yes |
||||||
Grid monitoring |
yes |
||||||
Anti-islanding protection |
yes |
||||||
Residual-current monitoring unit |
yes |
||||||
AFCI protection |
Optional |
||||||
General data | |||||||
Dimensions (W / H / D) |
375/350/160mm |
||||||
Weight |
10.8kg |
||||||
Operating temperature range |
–25°C … +60°C |
||||||
Noise emission (typical) |
≤35 dB(A) |
||||||
Nighttime power consumption |
< 1W |
||||||
Topology |
Transformerless |
||||||
Cooling |
Natural convection |
||||||
Protection degree |
IP65 |
||||||
Relative humidity |
0-100% |
||||||
Altitude |
4000m |
||||||
DC connection |
H4/MC4(Optional) |
||||||
AC connection |
Connector |
||||||
Display |
OLED+LED/WIFI+APP |
||||||
Interfaces: RS485 / USB/Wi-Fi/ GPRS/ RF/LAN |
Yes/Yes/Optional/Optional/Optional /Optional |
||||||
Warranty: 5 years / 10 years |
Yes /Optional |
||||||
CE, IEC62109, VDE0126-1-1, AS4777, AS/NZS 3100, VDE-AR-N4105, CQC, IEC61683, IEC60068, IEC61727, IEC62116, INMETRO |
MIN 2500-6000TL-XE
Datasheet |
MIN 2500TL-XE |
MIN 3000TL-XE |
MIN 3600TL-XE |
MIN 4200TL-XE |
MIN 4600TL-XE |
MIN 5000TL-XE |
MIN 6000TL-XE |
Input data (DC) | |||||||
Max. recommended PV power (for module STC) |
3500W |
4200W |
5040W |
5880W |
6440W |
7000W |
8100W |
Max. DC voltage |
500V |
500V |
500V |
500V |
500V |
500V |
500V |
Start Voltage |
100V |
||||||
Nominal voltage |
360V |
||||||
MPP voltage range |
80V-500V |
80V-500V |
80V-550V |
80V-550V |
80V-550V |
80V-550V |
80V-550V |
No. of MPP trackers |
2 |
||||||
No. of PV strings per MPP tracker |
1 |
||||||
Max. input current per MPP tracker |
12.5A |
||||||
Max. short-circuit current per MPP tracker |
16A |
||||||
Output data (AC) | |||||||
AC nominal power |
2500W |
3000W |
600W |
4200W |
4600W |
5000W |
6000W |
Max. AC apparent power |
2500VA |
3000VA |
3600VA |
4200VA |
4600VA |
5000VA |
6000VA |
Nominal AC voltage(range*) |
230V (180-280V) |
||||||
AC grid frequency(range*) |
50/60 Hz (45-55Hz/55-65 Hz) |
||||||
Max. output current |
11.3A |
13.6A |
16A |
19A |
20.9A | 22.7A | 27.2A |
Adjustable power factor |
0.8leading…0.8lagging |
||||||
THDi |
<3% |
||||||
AC grid connection type |
Single phase |
||||||
Efficiency | |||||||
MPPT efficiency |
98.20% |
98.20% |
98.20% |
98.40% |
98.40% |
98.40% |
98.40% |
European efficiency |
97.10% |
97.10% |
97.20% |
97.50% |
97.50% |
97.50% |
97.50% |
MPPT efficiency |
99.90% |
||||||
Protection devices | |||||||
MPPT efficiency |
Yes |
||||||
DC reverse polarity protection |
yes |
||||||
DC switch |
Type III / Type III |
||||||
AC/DC surge protection |
yes |
||||||
Insulation resistance monitoring |
yes |
||||||
AC short-circuit protection |
yes |
||||||
Ground fault monitoring |
yes |
||||||
Grid monitoring |
yes |
||||||
Anti-islanding protection |
yes |
||||||
Residual-current monitoring unit |
yes |
||||||
AFCI protection |
Optional |
||||||
General data | |||||||
Dimensions (W / H / D) |
375/350/160mm |
||||||
Weight |
10.8kg |
||||||
Operating temperature range |
–25°C … +60°C |
||||||
Noise emission (typical) |
≤35 dB(A) |
||||||
Nighttime power consumption |
< 1W |
||||||
Topology |
Transformerless |
||||||
Cooling |
Natural convection |
||||||
Protection degree |
IP65 |
||||||
Relative humidity |
0-100% |
||||||
Altitude |
4000m |
||||||
DC connection |
H4/MC4(Optional) |
||||||
AC connection |
Connector |
||||||
Display |
OLED+LED/WIFI+APP |
||||||
Interfaces: RS485 / USB/Wi-Fi/ GPRS/ RF/LAN |
Yes/Yes/Optional/Optional/Optional /Optional |
||||||
Warranty: 5 years / 10 years |
Yes /Optional |
||||||
CE, CEI 0-21, VDE-AR-N 4105, VDE 0126-1-1, UTE C 15-712-1, EN 50549, IEC 62116, IEC 61727, G99, C10/C11, UNE217001, UNE206007, PO12.2 |
MIN 2500-6000TL-XH
Datasheet |
MIN 2500TL-XH |
MIN 3000TL-XH |
MIN 3600TL-XH |
MIN 4200TL-XH |
MIN 4600TL-XH |
MIN 5000TL-XH |
MIN 6000TL-XH |
Input data (DC) | |||||||
Max. recommended PV power (for module STC) |
3500W |
4200W |
5040W |
5880W |
6440W |
7000W |
8100W |
Max. DC voltage |
500V |
500V |
500V |
500V |
500V |
500V |
500V |
Start Voltage |
100V |
||||||
Nominal voltage |
360V |
||||||
MPP voltage range |
80V-500V |
80V-500V |
80V-550V |
80V-550V |
80V-550V |
80V-550V |
80V-550V |
No. of MPP trackers |
2 |
||||||
No. of PV strings per MPP tracker |
1 |
||||||
Max. input current per MPP tracker |
12.5A |
||||||
Max. short-circuit current per MPP tracker |
16A |
||||||
Output data (AC) | |||||||
AC nominal power |
2500W |
3000W |
600W |
4200W |
4600W |
5000W |
6000W |
Max. AC apparent power |
2500VA |
3000VA |
3600VA |
4200VA |
4600VA |
5000VA |
6000VA |
Nominal AC voltage(range*) |
230V (180-280V) |
||||||
AC grid frequency(range*) |
50/60 Hz (45-55Hz/55-65 Hz) |
||||||
Max. output current |
11.3A |
13.6A |
16A |
19A |
20.9A | 22.7A | 27.2A |
Adjustable power factor |
0.8leading…0.8lagging |
||||||
THDi |
<3% |
||||||
AC grid connection type |
Single phase |
||||||
Efficiency | |||||||
MPPT efficiency |
98.20% |
98.20% |
98.20% |
98.40% |
98.40% |
98.40% |
98.40% |
European efficiency |
97.10% |
97.10% |
97.20% |
97.50% |
97.50% |
97.50% |
97.50% |
MPPT efficiency |
99.90% |
||||||
Protection devices | |||||||
MPPT efficiency |
Yes |
||||||
DC reverse polarity protection |
yes |
||||||
DC switch |
Type III / Type III |
||||||
AC/DC surge protection |
yes |
||||||
Insulation resistance monitoring |
yes |
||||||
AC short-circuit protection |
yes |
||||||
Ground fault monitoring |
yes |
||||||
Grid monitoring |
yes |
||||||
Anti-islanding protection |
yes |
||||||
Residual-current monitoring unit |
yes |
||||||
AFCI protection |
Optional |
||||||
General data | |||||||
Dimensions (W / H / D) |
375/350/160mm |
||||||
Weight |
10.8kg |
||||||
Operating temperature range |
–25°C … +60°C |
||||||
Noise emission (typical) |
≤35 dB(A) |
||||||
Nighttime power consumption |
< 1W |
||||||
Topology |
Transformerless |
||||||
Cooling |
Natural convection |
||||||
Protection degree |
IP65 |
||||||
Relative humidity |
0-100% |
||||||
Altitude |
4000m |
||||||
DC connection |
H4/MC4(Optional) |
||||||
AC connection |
Connector |
||||||
Display |
OLED+LED/WIFI+APP |
||||||
Interfaces: RS485 / USB/Wi-Fi/ GPRS/ RF/LAN |
Yes/Yes/Optional/Optional/Optional /Optional |
||||||
Warranty: 5 years / 10 years |
Yes /Optional |
||||||
CE, IEC62109, AS/NZS 4777.2, CEI 0-21, VDE-AR-N 4105, VDE 0126-1-1, UTE C 15-712-1,EN 50549, IEC 62116, IEC 61727, G98/G99 |
Core Values:
Honest
The company always adheres to the principles of people-oriented, honest operation, quality first, and customer satisfaction. The competitive advantage of our company is such a spirit, we take every step with a firm attitude.
Innovation
Innovation is the essence of our team culture. Innovation brings development, brings strength, Everything stems from innovation. Our employees innovate in concepts, mechanisms, technology and management. Our company is always active to adapt to changes in strategy and the environment and prepare for emerging opportunities.
Responsibility
Responsibility gives perseverance. Our team has a strong sense of responsibility and mission to customers and society. The power of this responsibility is invisible, but it can be felt. Has been the driving force of our company’s development.
Cooperation
Cooperation is the source of development, and creating a win-win situation together is regarded as an important goal of enterprise development. Through effective cooperation in good faith, we seek to integrate resources and complement each other so that professionals can give full play to their expertise.
Mission: Optimize the energy portfolio and take responsibility for enabling a sustainable future.
Vision: Provide an one-stop solution for clean energy.
* The AC voltage and frequency range may vary depending on specific country grid standard.
All specifications are subject to change without notice.
Selling Units: Single item
Single package size: 37.5X35X16 cm
Single gross weight: 10.800 kg
Package Type: Carton and wooden box or pallets
Lead Time:
Quantity(Units) | 1 - 5000 | >5000 |
Est. Time(days) | 15 | To be negotiated |